Overview
You can connect to the CT-E9 via a network or directly using your PC or laptop to access the built-in web server. Accessing the web server allows for extended parameter setup. It also includes Live Data view allowing the user to validate the lift controller inputs and messages being received.
Downloads
Details
Operating Voltage | 12 – 28V DC (absolute maximum 33V DC) |
---|---|
Operating Current | 65mA, 100mA with Wi-Fi Active |
Input Protocols | GAL CAN, OTIS RSL |
Output Interface | RS-485 |
Output Protocols | Pixel Technologies Mode 3 |
Pixel DataBus Length | Up to 64 nodes & 400m (max) |
Wi-Fi Access point | 802.11b/g/n |
Configuration | On-Device HTTP Webserver |
Status Indication | Status (RGB LED) |
Operating Temperature | 0 – 50°C |
Operating Humidity | 90% max relative humidity, noncondensing |
Mounting | Surface mounting or DIN Rail |
Dimensions (mm) | 68(W) x 95.6(H) x 15(D) |